On-Board System Protection
The MIOX system is engineered to be self-preserving.

MIOX equipment employs a number of features to protect the system — particularly the electrolytic cell — from undesirable operating conditions. A thermal monitoring system measures cell inlet and outlet temperatures to shut the system down if temperatures or cell flow are outside normal operating parameters. Use of three-way sample valves prevents the potential for blocked flows. Rupture discs automatically drain the cell should pressures exceed safe limits, protecting the cell from damage.
Product Engineering
that mixed oxidants can reduce formation of TTHMs by 20% to 50%?